We have collected all the error codes of Hotpoint Ariston induction cookers with a detailed description of the causes of malfunctions, diagnostics and repair. For convenience, arranged in a convenient and understandable table below.
The models with the display show the alphanumeric combination on your display, find it in the table and find out the reason for the error.
Models without a display do not execute the specified program and according to the lit or flashing lights placed on the control panel, you can find out the problem.
Error code | Description | Causes and solution |
---|---|---|
F03 | The sensor does not work due to a module malfunction. | The cause of the breakdown could be a circuit, improper installation and connection of the panel. Replacement of the touch keys module required. We recommend contacting customer service. |
F04 | There is no cooling, the problem is overheating of electronic components. | Overheating is triggered by unstable mains voltage. Need to replace the protection of the power supply, or the unit itself, contact the service for diagnostics and repair work. |
F05 | The large diameter hot plate heat sensor is out of order. | Try rebooting the device, reset all settings to factory defaults. The thermal sensor closes when the network is not stable. It is necessary to replace the heater or temperature sensors. |
F06 | Short circuit NTC sensor on a small burner. | A malfunction caused a short circuit or an open circuit. To fix the breakdown, replace the NTC sensor or its fuses. Repair is carried out by a service department. |
F07 | Faulty thermal sensor. | Often the problem is related to burnout of the electronic module or oxidation of the contacts between the wire and the heating element. Need to contact service for repair. |