Error code Description Causes and solution
E00 The heat sensor is defective. We recommend calling the technicians from the service center to diagnose and eliminate the breakdown. Do not operate the device until specialists arrive.
E01 The air temperature in the refrigerator compartment is critically high. The sensor reacts in critical cases. Problems due to wear of the evaporator, refrigerant leaks. Contact the service center.
E02 The temperature regime in the freezer compartment is violated. The door may have been closed loosely and the refrigerator compartment has become warmer. Press the doors harder, inspect the seal, replace it.
E03 Temperature rise to an unacceptable level. Problems arise not only from poorly closed doors. For example, the cooler is broken. Contact a service company to inspect the equipment.
E04 Temperature problems in the refrigerator compartment. Wrong operating mode and food selected, or the chamber is overloaded. Select a different operating mode on the temperature selector.
E05 The defrost system is malfunctioning. It is getting too cold in the food storage compartment. The foreman must inspect the device. Unplug and unload the cameras prior to his arrival.
E06 The heater is defective. Frost formation indicates a problem with the evaporator. A refrigeration repair specialist will be able to eliminate this defect.
E07 Defrosting does not work. The device does not defrost during operation, because of this ice and frost accumulates on the walls. Problems with the defrost system are eliminated in the service.
E10 Thermal sensors signal a failure of the operating temperature. Unstable operating temperatures negatively affect cooling performance. Contact service for replacement parts.
E11 Cooling problems. Poor cooling caused by refrigerant leakage or worn out fan. We recommend that you contact the repairman to fix the defects.
E20 The refrigerator door is not properly closed. The rubber seal is worn out or loose. Try to slam the door again. If it does not help, you need the services of a wizard from the service center.
E22 The temperature regime is broken in the refrigerating chamber. Cooling problems can be caused by a defective compressor. Listen to the noise of the equipment, call the master from the service.
E30 The refrigerator compartment does not cool the food properly. Hypothermia leads to spoilage of any food. Set the correct operating mode of the equipment, reduce the power of the cooler.
E33 Warm air in the refrigerator compartment. An increase in temperature is an unfavorable signal. We need a diagnostics of thermal sensors. Contact an equipment repair service to fix the breakdown.
E40 Food is being over-frozen due to an incorrect operating mode. In extreme cold, food deteriorates. Read the instruction manual and set the correct program.
E44 Critically low temperature. Ice formation on the walls is a serious problem. Call the service, and call the wizard to diagnose the equipment, replace faulty elements.