Error codes washing machine Ariston

We have collected all the error codes of Ariston washing machine with a detailed description of the causes of malfunctions, diagnostics and repair. For convenience, arranged in a convenient and understandable table below.

The models with the display show the alphanumeric combination on your display, find it in the table and find out the reason for the error.

Models without a display do not execute the specified program and according to the lit or flashing lights placed on the control panel, you can find out the problem.

Ariston washing machine errors, decoding

Error code Description Causes Solution
F01 A short circuit has occurred inside the motor control circuit. Water may have gotten onto the pins of the controller connector connected to the drive motor. Alternately swap email. controller, triac motor, drive motor.
F02 There is no signal from the sensor TAHO about the rotation of the motor to the controller. It is possible to lock the rotor of the motor due to jamming of the drum bearings. The rotor is checked for blocking, the electrical connection of the controller and the drive, the resistance of the winding TAHO (115 - 170 Ohms). When using an asynchronous drive in a washer, check the harness connecting the controller and motor. In case of breakage, the drive motor, el. controller.
F03 Water temperature sensor out of order. The sensor is faulty. Perhaps sticking sensor TEN. Check the connection of the temperature sensor and the controller; also the resistance of the temperature sensor should be within 20 kΩ at 20 ° C). In case of breakdown, the temperature sensor and controller need to be replaced.
F04 Water level sensor out of order. Possible overflow or empty tank. To diagnose the water level sensor. In case of breakdown, a level sensor and possibly an electronic controller need to be replaced.
F05 After draining the water, there is no signal of an empty tank. The problem is in the drain pump or level sensor. The drain pump is checked, during its start-up, the voltage at the contacts is measured. If there is no voltage at the contacts, the pump itself is checked (by applying 220 V to it). Another level sensor, filter with drain hose on a possible blockage. In case of breakdowns, the pump, pressure switch, el. controller.
F06 Error buttons. The code is displayed on washing machines in the AD series "Ariston Dialogic" There is no contact in the connection between the controller and the control panel. You need to make sure that the control panel buttons are working. In case of breakage, a new PU is installed.
F07 TEN heating does not heat the water. May not be immersed in water. For CM with EVO-I controllers: Check wiring, contacts in the controller, the efficiency of the relay heater. For EVO-II: Additionally, check the level sensor, measure the resistance of pins 5 and 6 of connector J3. If necessary, replace the heater, level sensor and electronic controller.
F08 The level sensor gives signals simultaneously overflow and empty tank. TEN relay for heating water stuck. Check pressostat, TEN. In case of breakage, new TEN and level sensor are installed. If these elements are intact, you need a replacement email. controller.
F09 Failure of non-volatile memory - Replacing the electronic controller. Overwrite chip non-volatile memory.
F10 Completely otstutsvie signals from the level sensor. - For EVO-I: Contact check in electronic controller connections, level sensor operation, wiring. For EVO-II: Additionally, the level sensor on the closed contacts 2-4 in the connector J3.
F11 No communication from the drain pump. Disconnected or broken wiring. EVO-I Check contacts CN1 and CNF, drain pump. EVO-II Optional connection from pins 8 and 9 of J9 connector. Winding resistance (must be at the level of 170 0m)
F12 There is no connection between the display module and the controller. - For EVO-I: Need diagnostics connectors SMS controller. EVO-II: J11 connector.
F13 Drying temperature control circuit failure - Check the operability of the connection between the CAN and the drying temperature sensor. Replace if necessary.
F14 Drying does not work - Check the connection between EC and drying TEN. Replacement of the electronic controller is possible.
F17 The hatch door is open. The door is not tightly closed. Check: The operability of the micro-switch lock the door. Reliability of fixing the door of the hatch. If necessary, replace the lock lock.
F18 Microprocessor error - Install a new electronic controller